2-Door Controller CT-V900-A
Features: Control 2 doors (Reader In / REX Out) or 1 Door (Reader In / Reader Out) Add up to 6 more doors to the CT-V900-A using the CA-A470-A expansion module 10,920 on-board card database 256 Schedules 256 Access Levels 2048 Event Buffer 16 on-board inputs (*using ATZ 2R/3R) 2 on-board 12 Vdc or 24 Vdc field-selectable lock outputs 2 on-board Form C dry contact relay outputs (N/O - N/C) Fully distributed database architecture (access decisions made locally) Flash firmware - Upload firmware via the Centaur Server E-Bus technology add-on hardware modules can be up to 1220m (4000ft) away from the CT-V900-A 2.5A switching power supply Supports common Wiegand, Track 2 ABA (mag stripe) and BCD (keypad) formats Easy maintenance with snap-off terminal blocks Battery backup functionality (2 x 12V 7AH gel-type batteries) Lithium battery protection in case of complete power failure Communication: RS-485 controller - expansion module network (9.6k or 19,2k baud) Connect modules up to 1220m (4000ft) away from the controller Plug and play technology RS-232 support to communicate with the Centaur software via serial port, dial-up or LAN Physical Specifications: Cabinet size: 39cm (15.5) high x 33cm (13) wide x 10cm (4) deep PCB dimensions: 24.5cm (9.65) x 20.2cm (7.95) Environment: 5°C to 55°C (41°F to 133°F) Electrical Specifications: Power input: 24Vac, 75VA or higher, 50/60Hz transformer Supply current: 2.5A maximum Battery capacity: Two 12Vdc, 7Ah, acid/lead gel cell batteries Input Specifications: Reader Inputs/Ports: 2 Keypad Inputs/Ports: 2 Multi-purpose Inputs: 16 (using ATZ 2R/3R) Output Specifications: 12/24Vdc Lock outputs: 2 Relays: 2 Form C Dry Contact 5A/30Vdc N.C/N.O. Reader Outputs: Six 50mA Open collector outputs (Red/Green LEDs, Buzzer) On-board Protection: Auxiliary outputs: 2.5A (24Vdc), 1A (12Vdc & 5Vdc) fuseless protection AC protection: 5A fuse Battery reversal: 7A fuse
______________________________________________
Elevator Controller CA-A480-A
Features: 16 on-board floor control relays Fire control input Control up to 64 floors and 2 elevator cabs Destination reporting (requires CA-A482-P Destination Reporting Module) Connects directly to the RS-485 E-BUS Backup battery with selectable battery charge current Individual schedules per floor with on-board 12Vdc power supply Fully supervised with comprehensive LED display Input Specifications Fire alarm: 1 Tamper: 1 Output Specifications Relay outputs: 16 form C relays rated at 20A/16Vdc, N.C./N.O |
|
For access to the user manuals please call
Vallance Security ask for a password.
Copyright © 2001 [Webmaster]. All rights reserved.
|